gx3-cli-mcp

mcp
Guvenlik Denetimi
Uyari
Health Uyari
  • License — License: NOASSERTION
  • Description — Repository has a description
  • Active repo — Last push 0 days ago
  • Low visibility — Only 5 GitHub stars
Code Gecti
  • Code scan — Scanned 12 files during light audit, no dangerous patterns found
Permissions Gecti
  • Permissions — No dangerous permissions requested

Bu listing icin henuz AI raporu yok.

SUMMARY

Trace a GX Works3 ladder without opening GX Works3 — read-only CLI + MCP server so anyone (or an AI agent) can find why a coil never turns on.

README.md

gx3-cli-mcp

PyPI
Python
CI
License
gx3-cli-mcp MCP server

Work out why a coil never turns on, without opening GX Works3.

Reads a GX Works3 .gx3 project on your own machine and answers questions
about it — where a device is written, what has to be true for a coil to turn
on, which conditions come from outside the PLC, which branches can never be
true. Read-only: it never writes back to the project.

It is a CLI, and the same analysis is a stdio MCP server, so an AI agent can
answer from indexed facts instead of guessing at a binary file.

日本語: 三菱電機 MELSEC の .gx3 を GX Works3 を開かずに解析する CLI / MCP
サーバーです。「このコイルがなぜ ON にならないか」をラダーから追います。
読み取り専用で、元のプロジェクトは書き換えません。

中文: 不用打开 GX Works3,也能分析三菱电机 MELSEC 的 .gx3 工程,
从梯形图追查「这个线圈为什么不导通」。只读,不改写原工程。
完整中文说明见 README.zh-CN.md


Install

pip install gx3-cli-mcp

Python 3.10+. Installs two console scripts: gx3-cli and gx3-mcp-server.

Try it in 30 seconds

No project needed — generate one:

gx3-cli synthetic-project demo.gx3 --profile demo-line
gx3-cli guide --root demo.gx3

guide reads the project and tells you which commands are worth running on it,
and why. That is the answer to "there are sixty commands, where do I start".

On a real project

gx3-cli doctor --root project.gx3        # does it read?
gx3-cli index-lite build --root project.gx3
gx3-cli xref build --root project.gx3
gx3-cli guide --root project.gx3         # what to run next

Then ask it something:

# where is this device written, and what reads it?
gx3-cli xref where-used M100 --root project.gx3

# why is this coil not turning on?
gx3-cli trace-device M100 --root project.gx3 --strict-logic --compact

# the whole program, one line per rung
gx3-cli rung-text --root project.gx3

# search the comment you remember, not the device number you don't
gx3-cli query-comment "clamp pressure" --root project.gx3

Every command takes --format json for scripting, and -o FILE to write
instead of print. gx3-cli --help lists all of them by group.

Passing a .gx3 extracts it to .gx3_cache/<sha256>/ and analyses that copy.

What it can tell you

Question Command
Why is this coil off? trace-device, interlock-check
Where is this device written or read? xref where-used, xref downstream
What does this program do? rung-text, ladder-print, metrics
Show me the rung as a picture ladder-layout --format svg
What comes from outside the PLC? external-inputs, comm-refresh
What can never be true? dead-logic
What looks wrong? lint PROJECT (duplicate coils, multi-writer, operand widths, types)
What changed between versions? diff, semantic-diff
Did it read the project correctly? roundtrip

Use with an AI agent

{
  "mcpServers": {
    "gx3": { "command": "gx3-mcp-server" }
  }
}

Or "command": "python", "args": ["-m", "gx3cli.gx3_mcp_server"] if your
client cannot resolve console scripts from PATH. The server exposes read-only
analysis tools and a restricted command runner.

See Agent usage guide (JA) for how an agent should
drive it.

Scope, honestly

Read-only analysis of .gx3 on your machine. Ladder is what it reads well.
FBD, ST, SFC and MIL are detected and reported as such rather than guessed at,
so a program it cannot read comes back saying so instead of coming back empty.

It does not edit projects, connect to a PLC to change anything, or replace GX
Works3. live-read can read live device values over MC Protocol/SLMP, CLI-only
and only with explicit connection parameters.

Output is advisory. Verify in GX Works3 and through your own safety process
before touching real equipment. See
Validation matrix (JA) for what has been checked.

If a project fails to parse, gx3-cli failure-corpus capture turns it into a
local regression sample without sending anything anywhere.

Troubleshooting

7z-style .gx3 — install 7-Zip, or point at it:
set GX3_7Z=C:\Program Files\7-Zip\7z.exe. Encrypted containers are not
decrypted; export the folder from GX Works3 instead.

PyPI blockedpip install git+https://github.com/purinzan/gx3-cli-mcp.git

Something reads wronggx3-cli doctor --root ... first, then
open an issue.

Documentation

Agent skills: existing project audit
· failure corpus

Analysis contract migration

Current query-by-query status and remaining acceptance work for #153: 解析契約の移行台帳.

License

Source-available, not open source. Full terms in
LICENSE.txt; this is a summary and the license text governs.

You may read the source and run it for evaluation and internal work,
including inside a company. You may not redistribute it, host it as a
service, or ship it in a paid product without written permission. There is no
licence key, activation or paid plan.

日本語: 社内での評価・業務利用は許諾されています。禁止しているのは再配布、
SaaS 提供、有償製品への組み込みです。実行にライセンスキーや課金は不要です。
商用利用の相談は Issue からどうぞ。

Listed on Glama

Indexed as an MCP server, with per-tool scores for how well each tool
describes what it does. Useful as outside feedback on the tool surface —
the low scores there are the ones whose descriptions need work.

gx3-mcp-server on Glama

Contributing: CONTRIBUTING.md · AGENTS.md

Yorumlar (0)

Sonuc bulunamadi